How tenants can influence heating and cooling

Selecting green office tenancies

In Australia all sellers or lessors of office space of 2,000 square metres or more are required to obtain and disclose a current Building Energy Efficiency Certificate (BEEC) which includes an energy star rating and lighting assessment. Heating and cooling efficiency is a major determinant of the base building’s rating. When tenants require green office space it drives up the priority for facilities managers to provide high performing base building services.

See more: 
Leasing best practice >> 
Commercial Building Disclosure (CBD) >>

 

Energy efficiency

Many efficiency actions that tenants identify and implement through a planning process will cut waste heat from their equipment. Any reductions in heat load on the floor will take pressure off the heating and cooling systems – for example, after-hours lighting timers, computer shut-downs, and photocopier sleep modes.

See more:
Lighting energy efficiency >>
Equipment energy efficiency >>

Working with building management

By engaging with the facilities manager, tenants can be more active in helping to optimise their heating and cooling effectiveness. Some key measures to reduce HVAC and energy waste are:

  • Check that staff are familiar with the contents of the Building User Guide or request one from the facilities manager.
  • Make staff aware of how to operate advanced features of the HVAC and lighting system.
  • Ensure that staff do not operate personal heaters and other appliances which could significantly increase energy consumption of the tenancy and also affect the operation of the base building HVAC systems.
  • Understand and discuss building set-points with the facilities manager.
  • Where possible, encourage staff working after-hours and on weekends to use areas that are served by supplementary HVAC systems. Often, meeting rooms have such systems installed, which are more economical and efficient to operate, rather than using the base building HVAC systems – which is expensive and inefficient if only needed for small areas.
  • Ensure windows and doors are kept closed when the building is unoccupied during the heating or cooling seasons. Report any gaps in sealing which cause air leakage and draughts to the facilities manager.
  • During summer close window shading devices to reduce air conditioning loads. During winter when it is dark outside, close window shading devices to reduce heat losses through radiation.
  • Check that HVAC systems are switched off after-hours and that cleaning staff do not have access to operate HVAC systems wastefully.
  • Encourage staff to dress for the season to accommodate small increases in internal temperature range.

Considerations for fit-out

The guiding principle for fit out is to not work against or undo any optimisation strategies that the building manager is carrying out. Some examples are:

  • Ensure that tenancy fit-out guidelines issued by the building owner are observed during renovations and upgrade.
  • When installing space partitioning during office fit-outs, ensure the use of natural lighting is not obstructed and the operation of HVAC systems is not affected.
  • When carrying out tenancy fit-outs, ensure that the lighting power density does not exceed BCA Section J requirements and complies with the tenancy fit-out guidelines. Lighting produces heat, which must be removed by air conditioning systems, which wastes energy.


Categories:
Tags:

Related resources

Why Expand the Band - a factsheet for building owners

Why Expand the Band - a factsheet for building owners

Over heating or cooling your building?  This factsheet will show you how we can provide better occupant comfort, save money and reduce emissions by expanding the band.

Why Expand the Band - a factsheet for Tenants

Why Expand the Band - a factsheet for Tenants

Increase productivity, reduce emissions and save money.  This factsheet will explain how.

Bring your Best Self- Campaign Posters

Bring your Best Self- Campaign Posters

Download these fun 'Bring your Best Self' posters to use in your office. 

BCO Guide to improving the environmental performance of offices

A guide by the British Council for Offices providing methods to measure building performance, occupant satisfaction, case studies and more. The report says that high performance can create productivity improvements that swamp utilities costs.

A guide to office building quality

A Property Council of Australia document providing tools for assessing office building quality in new and existing buildings. The tools provide a guide to parameters that typically influence building quality, offering a voluntary, market based approach.

Low Energy High Rise Project

Research and information for building operators by the Warren Centre showing how NABERS ratings can be improved but up to one star, with very low or no capital cost.

EEX: Heating, Ventilation and Air-conditioning

A comprehensive resource from the Energy Efficiency Exchange on reducing demand, optimising service, and upgrading HVAC services to improve overall energy performance.

Video: what affects occupant comfort?

Occupant comfort, indoor temperatures and energy consumption are are linked. In this video, Sydney University's world-expert on the topic, Prof. Richard de Dear explains the different dimensions impacting occupant comfort at a Better Buildings Partnership event.

Best Practice Maintenance and Operation of HVAC Systems for Energy...

HVAC maintenance and operation techniques can be adjusted to save money, reduce emissions and keep occupants comfortable. This Australian Government guide and fact sheets are for  those working with the maintenance and operation of HVAC systems,to help improve energy and water efficiency.

Search resources